Filters
Question type

Study Flashcards

The ____ instruction stops the processor from scanning the rest of the program.


A) LBL
B) IOT
C) TND
D) STI

E) All of the above
F) A) and B)

Correct Answer

verifed

verified

The use of the immediate I/O instruction increases the total scan time of the program.

A) True
B) False

Correct Answer

verifed

verified

Immediate instructions should be used only when:


A) a program must be halted immediately.
B) a program must be restarted immediately.
C) the updating of an input or output is critical to your operation.
D) the resetting of all bits in the data table is critical to your operation.

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

Master control reset (MCR)and jump (JMP)are often referred to as override instructions.

A) True
B) False

Correct Answer

verifed

verified

When an MCR zone goes false,off-delay timers within the zone will automatically activate and begin their off delay cycle.

A) True
B) False

Correct Answer

verifed

verified

A latch instruction will automatically unlatch if it is contained within a de-energized MCR zone.

A) True
B) False

Correct Answer

verifed

verified

Each JMP instruction must have a LBL instruction.

A) True
B) False

Correct Answer

verifed

verified

The label address must match that of the jump instruction with which it is used.

A) True
B) False

Correct Answer

verifed

verified

The label (LBL) instruction is:


A) always logically true.
B) has the same address as the jump instruction with which it is used.
C) is used to identify the ladder rung that is the target destination of the JMP instruction.
D) all of these.

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

Emergency stop circuits should be hardwired outside of the controller program so that,in the event of total controller failure,independent and rapid shutdown means are available.

A) True
B) False

Correct Answer

verifed

verified

You must energize the MCR instruction to activate it.

A) True
B) False

Correct Answer

verifed

verified

The forcing function of a PLC allows the user to turn an external input or output on or off:


A) according to the forced program.
B) according to the main program.
C) from the keyboard regardless of its actual status.
D) all of these.

E) None of the above
F) All of the above

Correct Answer

verifed

verified

Which of the following PLC instructions would not be classified as an override instruction?


A) Master control reset
B) Jump-to-subroutine
C) Output energize
D) Jump-to-label

E) A) and D)
F) B) and C)

Correct Answer

verifed

verified

The fenced zone controlled by the MCR instruction is (are) : The fenced zone controlled by the MCR instruction is (are) :   A) rungs No.1 through No.8. B) rungs No.3 through No.6. C) rungs No.2 and No.6. D) rung No.2.


A) rungs No.1 through No.8.
B) rungs No.3 through No.6.
C) rungs No.2 and No.6.
D) rung No.2.

E) None of the above
F) A) and B)

Correct Answer

verifed

verified

Programming the selectable timed interrupt is done when a section of program needs to be executed on a time basis rather than on an event basis.

A) True
B) False

Correct Answer

verifed

verified

The JMP instruction does not contribute to logic continuity and,for all practical purposes,is always logically true.

A) True
B) False

Correct Answer

verifed

verified

The immediate I/O instruction is used with critical I/O devices that require updating in advance of the I/O scan.

A) True
B) False

Correct Answer

verifed

verified

The ____ is the target for the jump instruction.


A) LBL
B) TND
C) IOT
D) RET

E) A) and B)
F) A) and C)

Correct Answer

verifed

verified

Assume the processor comes equipped with a normally closed fault relay contact output designed to open when a processor malfunction is detected.This contact would be: Assume the processor comes equipped with a normally closed fault relay contact output designed to open when a processor malfunction is detected.This contact would be:   A) programmed as part of the master control reset instruction. B) programmed as part of the zone control last state instruction. C) hardwired in series with the emergency stop button. D) hardwired in parallel with the emergency stop button.


A) programmed as part of the master control reset instruction.
B) programmed as part of the zone control last state instruction.
C) hardwired in series with the emergency stop button.
D) hardwired in parallel with the emergency stop button.

E) C) and D)
F) B) and D)

Correct Answer

verifed

verified

It is not possible to jump backward in the program.

A) True
B) False

Correct Answer

verifed

verified